Instruction Manual
and Experiment Guide
for the PASCO scientific
Model SP-9268A
012-02135F
10/03
STUDENT
SPECTROMETER
Copyright © January 1991 $7.50
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - SPECTROMETER

betterteach scienceways toPhone (916) 786-3800 • FAX (916) 786-8905 • email: [email protected] Foothills Blvd. • P.O. Box 619011 • Roseville, CA

Strany 2

6Student Spectrometer 012-02135F¨9. Repeat steps 6-8 until the angles for the correspond-ing slit images are the same to within one minute ofarc.Makin

Strany 3 - Table of Contents

7012-02135F Student Spectrometer¨To Measure the Angle of MinimumDeviation:1.Align and focus the spectrometer as described earlier.2. Use the two thumb

Strany 4 - Equipment Return

8Student Spectrometer 012-02135F¨MaintenanceIMPORTANT: Always handle the spectrometerand its accessories with care to avoid scratchingthe optical sur

Strany 5 - Introduction

9012-02135F Student Spectrometer¨The optional Gaussian eyepiece (Model SP-9285) sim-plifies the task of aligning and focusing the spectrometerand alig

Strany 6 - Equipment

10Student Spectrometer 012-02135F¨13. Illuminate the slit with an external light source. Ro-tate the telescope directly opposite the collimatorand foc

Strany 7 - Equipment Setup

11012-02135F Student Spectrometer¨Technical SupportFeedBackIf you have any comments about this product or thismanual please let us know. If you have a

Strany 8 - VER I'

Model Name 012–0xxxxA34

Strany 10 - Using the Prism

012-02135F Spectrometer®iSection PageEquipment Return ...iiI

Strany 11 - PRISM CLAMP

Spectrometer 012-02135F®iiEquipment ReturnShould this product have to be returned to PASCOscientific, for whatever reason, notify PASCO scientificby

Strany 12 - Maintenance

1012-02135F Student Spectrometer®COLLIMATORSLITRED LIGHTTELESCOPECOLLIMATORLIGHTSOURCEPARALLEL BEAMDIFFRACTION GRATING(OR PRISM)GREEN LIGHTANGLE OFDIF

Strany 13

2Student Spectrometer 012-02135F®EquipmentThe PASCO scientific Model SP-9268A Student Spec-trometer provides precise spectroscopic measurementsusing e

Strany 14 - Alignment Error

3012-02135F Student Spectrometer¨Equipment SetupNOTE: If you are using the optional GaussianEyepiece (SP-9285), equipment setup is somewhatsimpler th

Strany 15 - Technical Support

4Student Spectrometer 012-02135F¨2. The mounting pillars of the telescope and collimatorcan be rotated by using an Allen wrench to loosen thescrews th

Strany 16 - Model Name 012–0xxxxA

5012-02135F Student Spectrometer¨Using the Diffraction GratingIMPORTANT: The Diffraction Grating is a deli-cate component. Be careful not to scratch